Solder point T12 4,6Ok so K8 and K9 are receiving the correct control signal. That’s good. K7 is fine; it won’t have 12 volts DC across pins 1 & 10 unless the “COMP” button is on.
Try turning EQ and COMP off, but turn EQ>COMP on. Send the sine wave into line in. Set the meter dial to 200V AC. Hold the black probe on any convenient grounded place, such as solder point 12, 15, or T7. Then with the red probe measure the AC at these points:
Solder point T12
K8 pin 2
K8 pin 3
K8 pin 4
K8 pin 7
K8 pin 8
K8 pin 9
All the same pins on K9
Solder point 64
Edit: measure on K8 & K9, not K7
K8/9 pin 2 4,5/0
K8/9 pin 3 0/4,6
K8/9 pin 4 0/4,6
K8/9 pin 7 0/4,6
K8/9 pin 8 0/4,6
K8/9 pin 9 0/0
Solder point 64 0